Page B1.2 . 24 May 2000                     
ArchitectureWeek - Building Department
NEWS   |   DESIGN   |   BUILDING   |   DESIGN TOOLS   |   BUILDING CULTURE
BUILDING
 
  •  
  • Building for "Harmony with Nature"
     
  •  
  • Dirt-Cheap Houses from Elemental Materials
     
  •  
  • Maybeck Returns to Oregon
     
  •  
  • Saitama Super Arena: Three Buildings in One

     
    AND MORE
      Current Contents
      Blog Center
      Book Center
      Download Center
      New Products
      Classic Home
      Competitions
      Conferences
      Events & Exhibits
      Architecture Forum
      Architects Directory
      Library & Archive
      Web Directory
      Marketplace
      About ArchWeek
      Search
      Subscribe & Contribute
      Newsletter Free
       

     
    QUIZ

    Building for "Harmony with Nature"

    (continued)

    The air distribution system, with supply at the floor and exhaust at the ceiling, works differently from a conventional ceiling supply and exhaust. A typical supply system mixes the entire room volume, maintaining air quality by diluting pollutants.

    By contrast, the floor supply system does not rely on global mixing. Instead, each person receives air from a floor grille, with air quality achieved due to the proximity of the supply to the occupant. Pollutants rise on air currents to the ceiling exhaust. A significant proportion of convective heat gains from lights, equipment, and people are exhausted before they become a load on the ventilation system. Comfort temperatures are maintained in the occupied zone only, while temperatures near the ceiling are typically several degrees higher.

    The pressurized floor plenum is very flexible. When cubicle or desk arrangements change, the tile with the supply grille can be moved. If cooling loads increase in a particular area, more floor grilles can be added there. The round floor grille comes with a twist damper that can be adjusted by the occupant to change the airflow into the space. Allowing occupants to tune their own work area can eliminate complaints from those not satisfied by average conditions.

    The major orientation of the building to face north and south maximizes use of natural light. Light sensors at the perimeter dim the electric lights whenever daylight is sufficient. Shades on the south side block unwanted direct sunlight while reflecting light onto the ceiling of the interior.

    This design lowers energy costs, and improves indoor air quality, and maximizes daylight. The owners expect that one outcome will be a more creative, motivated, and engaged workforce. Additional sustainability features include certified sources for all woods, recycled carpet yarns, and workstation fabrics.

    AW

    ArchWeek Photo

    Each floor has a family-style hearth with casual furnishings.
    Photo: Paul Warchol

    ArchWeek Photo

    On the south side, smaller windows with external shades limit solar gain but allow daylight penetration.
    Photo: Ove Arup & Partners

    ArchWeek Photo

    Two large glassed atriums connect all three floors.
    Photo: Paul Warchol

    ArchWeek Photo

    The open work space is built over a raised floor for wire management and HVAC distribution.
    Photo: Paul Warchol

     
    < Prev Page Next Page > Send this to a friend       Advertising       Contributing       Privacy       Comments
    GREAT BUILDINGS   |   DISCUSSION   |   SCRAPBOOK   |   COMMUNITY   |   BOOKS   |   FREE 3D   |   ARTIFICE   |   SEARCH
      ArchitectureWeek.com © 2000 Artifice, Inc. - All Rights Reserved